The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
A large-scale implementation of distributed generation (DG) for households involves each house generating its energy from photovoltaic (PV) cells. This approach is particularly suitable in rural electrification projects where demand is relatively low and yet grid connection is costly. A meshed microgrid is an attractive solution for energy generation and sharing in domestic electrification projects...
Modern microprocessor-based low-impedance differential relays use a percentage differential principle that utilizes traditional dual slope characteristics. Many differential mis-operations occur with these traditional methods as a result of CT saturation, DC offset, or current subsidence. One reason is because the traditional operating and restraining principles rely heavily on the current magnitude,...
This paper presents a new multi-criteria stabilization algorithm of transformer differential protection. Proposed scheme bases on new criteria signals and appropriate operation thresholds. New algorithm employs fuzzy reasoning technique for better discrimination of inrush conditions. The developed stabilization algorithm has been tested with ATP-EMTP generated signals, proving to be reliable and much...
This paper aims to present the modeling and simulation of numerical differential protection of power transformers using the software ATP/ATPDraw and its MODELS environment. In order to validate the relay model, simulations were carried out using a simplified electrical power system whose parameters were obtained from a real system. The results reveal the advantages of using this type of modeling,...
The paper will present implemented protection scheme on two, symmetrical, double core design Phase Shifting Transformers (PST) [6], each rated at 600MVA, 400kV, 866A, 50Hz, ±40° with in total 64 tap positions (32 advance and 32 retard). Thus, every individual tap introduce phase angle shift of 1,25°. The used PST protection scheme follows the protection recommendations published by IEEE [1]. It shall...