The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper investigates a number of design, operation and lifetime management experiences of transformer protection systems installed on National Grid Electricity Transmission (NGET) networks. The paper will consider the policy, application design and operational experiences under the following categories particularly since the move to numeric protection: Policy and application design Operational...
This paper presents the results of the analysis of a vast fault records database. The fault records were obtained during numerous experiments performed from 2005 to 2011 in real resonant-earthed distribution networks. The purpose of these experiments was to provide data either for verifying distribution network safety during earth faults or for testing methods of earth fault location or elimination...
This paper presents a new multi-criteria stabilization algorithm of transformer differential protection. Proposed scheme bases on new criteria signals and appropriate operation thresholds. New algorithm employs fuzzy reasoning technique for better discrimination of inrush conditions. The developed stabilization algorithm has been tested with ATP-EMTP generated signals, proving to be reliable and much...
This paper presents an analysis of the main operating conditions that may lead to inappropriate differential protection operation. These conditions were simulated using the Alternative Transients Program (ATP) and the model of a real system. The saturable transformer was the main component of the ATP/EMTP simulations. The saturation and hysteresis effects are represented by a non-linear model of the...
High impedance fault (HIF) exposes great hazard for personal safety and property security. High impedance fault (HIF) in MV distribution with restricted fault current cannot be detected and cleared by conventional over current relays. In this paper, an integrated scheme utilizing different features of HIF is presented. Various documented field data has been investigated and summarized to get the most...
Transformer differential protection schemes normally use multi slope characteristics to provide stability during CT saturation with 2nd harmonic restraint or blocking for inrush conditions. This paper presents new algorithms that have been developed to improve the performance of the differential protection. Extensive testing has been used to demonstrate that the transient bias algorithm can reduce...
This paper aims to present the modeling and simulation of numerical differential protection of power transformers using the software ATP/ATPDraw and its MODELS environment. In order to validate the relay model, simulations were carried out using a simplified electrical power system whose parameters were obtained from a real system. The results reveal the advantages of using this type of modeling,...
To feed electric train, the structure of traction power supply system is very different from utility grid. The single-phase traction loads result in some problems, such as negative sequence, harmonics, reactive power and crossing neutral sections. Based on the existing traction power supply system, the active power filter is used to construct cophase traction power supply system. It not only eliminates...
This paper reviews the characteristics of inrush current and analyses its causes. The development of digital substation and the concept of integrated protection are also outlined. The paper studies different models to simulate several kinds of inrush and internal short-circuit fault. Through these models, the new composite algorithm is analysed in order to verify the reliability and sensitivity of...
With the increased use of renewable wind energy, wind farms are being built in remote areas, often far from load centers. The required long transmission lines are often constructed with series capacitive compensation to electrically shorten the lines. Events in the transmission system can cause interactions between the series capacitors and the system's inherent impedance which can result in sub-synchronous...