The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The paper presents a fingertip photoplethysmography (PPG) based technique to estimate the pulse rate of the subject. The PPG signal obtained from a pulse oximeter is used for the analysis. The input samples are corrupted with motion artifacts due to minor motion of the subjects. Entropy measure of the input samples is used to detect the motion artifacts and estimate the pulse rate. A three step methodology...
This paper presents a coarse-to-fine combined method for dealing with large displacement situations caused by low speed of frame rate in microscopic video sequences. Motion image estimation method utilizes the modified block matching method based on image warping to perform a wide range of changes in the amount of search comparison, and then using the optical flow method to fine adjustment pixel by...
Quantitatively assessing the tissue stiffness with acoustic radiation force impulse (ARFI) method has proved its worth in clinical trials. Much attention has been focused on the research of the displacement estimation algorithm in ARFI. However, the subsequent shear wave speed estimation part can also affect the accuracy and reliability of the results. In this study, several algorithms for shear wave...
Acoustic radiation force impulse (ARFI) technique is a quantitative method for tissue stiffness assessment. It has been proved to be less operator dependent than the quasi-static elastography, and has more simple hardware architecture than the supersonic shearwave imaging (SSI) technique, which make it easier to be miniaturized for some special clinical applications. However, unlike the SSI, ARFI...
This paper presents a new method for identification of system models that are linear in parametric structure, but arbitrarily nonlinear in signal operations. The strategy blends traditional system identification methods with three modeling strategies that are not commonly employed in signal processing: linear-time-invariant-in-parameters models, set-based parameter identification, and evolutionary...
Common Spatial Pattern (CSP) methods are widely used to extract the brain activity for brain machine interfacing (BMI) based on electroencephalogram (EEG). For each mental task, CSP methods estimate a covariance matrix of EEG signals and adopt the uniform average of the sample covariance matrices over trials. However, the uniform average is sensitive to outliers caused by e.g. unrelated brain activity...
3D stereophotography is rapidly being adopted by medical researchers for analysis of facial forms and features. An essential step for many applications using 3D face data is to first crop the head and face from the raw images. The goal of this paper is to develop a reliable automatic methodology for extracting the face from raw data with texture acquired from a stereo imaging system, based on the...
Independent component analysis (ICA) has been widely applied to identify brain functional networks from multiple-subject fMRI. However, the best approach to handle artifacts is not yet clear. In this work, we study and compare two ICA approaches for artifact removal using simulations and real fMRI data. The first approach, recommended by the human connectome project, performs ICA on individual data...
Stature is an important biological characteristic considered in the clinical activities. Height (h)is frequently hard to measure in the elderly population or in people with skeletal deformities and vertebral fractures. Furthermore it represents also a key point in forensic evaluations. Our aim was to provide an equation in order to predict human height based on the Longitudinal Scapular Diameter(LSD)...
It has been shown that Electrical Properties d(EPs) of biological tissues can be derived from MR-based B1 measurement. A strong appeal for these ‘Electrical Property Tomography’ (EPT) methods is to estimate real-time and subject-specific local specific absorption rate (SAR) induced by RF transmission. In order to investigate the feasibility of EPT-based local SAR estimation, following previously proposed...
This paper presents a monocular camera (MC) and inertial measurement unit (IMU) integrated approach for indoor position estimation. Unlike the traditional estimation methods, we fix the monocular camera downward to the floor and collect successive frames where textures are orderly distributed and feature points robustly detected, rather than using forward oriented camera in sampling unknown and disordered...
Record linkage is the task of identifying which records from one or more data sources refer to the same entity. Many record linkage methods were introduced and applied over the last decades. In general, the principle is to compare a range of available identifier fields in record pairs among different data sources, in order to make a linkage decision. The Fellegi-Sunter probabilistic record linkage...
Spatially-varying signal content can be effectively modeled using amplitude modulation-frequency modulation (AM-FM) representations. The AM-FM representation allow us to extract instantaneous amplitude (IA) and instantaneous frequency (IF) components that can be used to measure non-stationary content in biomedical images and videos. This paper introduces a new method for estimating the IA and the...
This paper presents a method to automatically estimate lung tidal volumes from the acoustic signals generated in the respiratory track. The signal is measured with an acoustic based sensor placed in the suprasternal notch. The method does not require any previous knowledge or modelling of the individual respiratory track, and relies on just one calibration parameter. The proposed algorithm is tested...
T∗2 mapping or R∗2 mapping for brain function offers advantages such as providing quantitative measurements independent of the MRI acquisition parameters (e.g. echo time TE). However, magnetic field susceptibility in the human brain can prevent an accurate estimation of R∗2, which in turn impacts the ability to study brain function. The present work investigates the effects of in-plane magnetic susceptibility-induced...
During physiological gait, humans continuously modulate their knee stiffness, depending on the demands of the activity and the terrain. A similar functionality could be provided by modern actuators in transfemoral prosthesis. However, quantitative data on how knee stiffness is modulated during physiological gait is still missing. This is likely due to the experimental difficulties associated with...
This study proposes an intervention for stroke patients in which electrical stimulation of muscles in the affected arm is supplied when movement intention is detected from the electroencephalographic signal. The detection relies on the combined analysis of two movement related cortical patterns: the event-related desynchronization and the bereitschaftspotential. Results with two healthy subjects and...
This paper proposed a method to monitor systolic blood pressure (BP) variability without using a cuff during the daytime. In this method, BP variability of long-term and short-term were separated and estimated respectively from features of phoplethysmograph (PPG) through the use of a frequency filter. Then, total variability was obtained from the combination of long-term and short-term. BP by using...
Wearable monitoring systems have gained tremendous popularity in the health-care industry, opening new possibilities in diagnostic routines and medical treatments. Numerous hardware systems have been presented since, which allow for continuous acquisition of various biosignals like the ECG, PPG, EMG or EEG and which are suited for ambulatory settings. Unfortunately, these flexible systems are liable...
Quasi-periodic signals can be modeled by their second order statistics as Gaussian process. This work presents a non-parametric method to model such signals. ECG, as a quasi-periodic signal, can also be modeled by such method which can help to extract the fetal ECG from the maternal ECG signal, using a single source abdominal channel. The prior information on the signal shape, and on the maternal...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.