The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
This paper describes an integrated system for facing heart failures (HF) in an innovative way. Existing left ventricular assist devices (LVAD or VAD) are usually devoted to blood pumping without the possibility to adapt the speed to patient conditions during everyday activities. This is essentially due to the lack of sensorization, bulkiness, and the need of relying on device-specific controllers...
In the presence of unpredictable disturbances and uncertainties, cells intelligently achieve their goals by sharing information via cell-cell communication and making collective decisions, which are more reliable compared to individual decisions. Inspired by adaptive sensor network algorithms studied in communication engineering, we propose that a multi-cellular adaptive network can convert unreliable...
High-level spinal cord injury (SCI) survivors face every day two related problems: recovering motor skills and regaining functional independence. Body machine interfaces (BoMIs) empower people with sever motor disabilities with the ability to control an external device, but they also offer the opportunity to focus concurrently on achieving rehabilitative goals. In this study we developed a portable,...
This paper presents a lower body reaction test that utilizes a new portable ultra-sound based motion capture system (MobiFit) combined with a synchronized visual stimulus. This novel system was tested first for criterion validity and agreement against a gold standard laboratory based optical motion capture system (CODA). It was subsequently tested in the field during Gaelic football (GAA) team gym...
This paper proposes a low-power fall detection algorithm based on triaxial accelerometry and barometric pressure signals. The algorithm dynamically adjusts the sampling rate of an accelerometer and manages data transmission between sensors and a controller to reduce power consumption. The results of simulation show that the sensitivity and specificity of the proposed fall detection algorithm are both...
In recent years a specialist interest has developed worldwide in advanced wound management for difficult to heal chronic wounds. Further progress in advanced wound management will require an improvement in personalized medicine for the patient and in particular an improvement in the availability of diagnostic tests and parameters that fulfil clinical need in wound management decisions. However, without...
A Device to detect for the bladder which is full with urine is designed. The device can measure bladder pressure. The pressure signals are processed. When the pressure exceeds 40cm water column, Pressure signal exceeds a fixed voltage. At the same time, Oscillator sends a signal and the signal transmits to the body surface. The receiver accepts the oscillating signal. Then, the alarm alerts. Liquid...
Pressure ulcers, commonly called bedsores, are defined as injuries to the skin and underlying tissue resulting from prolonged pressure usually on bony areas of the body, such as heels and hips. In order to alleviate pressure accumulation at high-risk regions, the current practice in clinics requires caregivers to reposition their patients every two hours. This relies on the engagement of nursing services...
Despite the growing incidence and costs of autism, little has been done to apply technology advancements to the challenges faced by autistic individuals. The recent introduction of digital data collection to track the progress of treatment interventions has been an important contribution, but there are many other opportunities for technology to facilitate the development of autistic children and to...
With an ever-growing number of technologically advanced methods for the diagnosis and quantification of movement disorders, comes the need to assess their accuracy and see how they match up with widely used standard clinical assessment tools. This work compares quantitative measurements of hand tremor in twenty-three Parkinson's disease patients, with their clinical scores in the hand tremor components...
In this paper we present a new method for passively measuring walking speed using a small array of radio transceivers positioned on the walls of a hallway within a home. As a person walks between a radio transmitter and a receiver, the received signal strength (RSS) detected by the receiver changes in a repeatable pattern that may be used to estimate walking speed without the need for the person to...
This paper presents the comparison of sleep-wake classification using electroencephalogram (EEG) and multi-modal data from a wrist wearable sensor. We collected physiological data while participants were in bed: EEG, skin conductance (SC), skin temperature (ST), and acceleration (ACC) data, from 15 college students, computed the features and compared the intra-/inter-subject classification results...
Extensive research has been conducted on the tracking and detection of the eye gaze and head movement detection as these aspects of technology can be applied as alternative approaches for various interfacing devices. This paper proposes enhancements to the classification of the eye gaze direction. Viola Jones face detector is applied to first declare the region of the eye. Circular Hough Transform...
The monitoring of physiological parameters such as heart rate, ventilatory rate, or oxygen saturation is a commonly used practice in the medical field. Many clinical solutions exist, based on the use of specific sensors, dedicated for bedside patient's vital functions monitoring at hospital. But the implementation of such sensors in ambulatory situations is rendered extremely difficult because of...
While scalp EEG/MEG source imaging have been extensively studied in the last two decades, the case of source localization from invasive measurements has resulted in few works to date. Yet there is a lot to gain from stereo-electroencephalographic (SEEG) recordings, providing high signal to noise ratio measurements of the explored brain structures. The SEEG setup consists in multi-contact electrodes...
The aim of this paper is to investigate the influence of mental fatigue on Positive 300 (P300) and Steady State Visual Evoked Potentials (SSVEP) during virtual wheelchair navigation. For this purpose, experimental protocols were setup in order to induce mental fatigue, P300 and SSVEP. Next, the correlation between mental fatigue and P300/SSVEP parameters were investigated. At the end, the best correlated...
In Wireless Body Area Networks (WBAN) the energy consumption is dominated by sensing and communication. Previous Compressed Sensing (CS) based solutions to EEG tele-monitoring over WBAN's could only reduce the communication cost. In this work, we propose a matrix completion based formulation that can also reduce the energy consumption for sensing. We test our method with state-of-the-art CS based...
Together with a charge or voltage amplifier, piezoelectric sensors are commonly used to pick up physiological vibrations from the body. As an alternative to chopper or auto-zero amplifiers, frequency sensing is known in literature to provide advantages of noise immunity, interfacing to digital readout systems as well as tunable range of sensing. A frequency-sensing readout circuit for sensing low...
The aim of this study was to analyze the changes that mild cognitive impairment (MCI) and Alzheimer's disease (AD) elicit in brain dynamics. For this task, the spontaneous magnetoencephalographic (MEG) activity from 36 AD patients, 18 MCI subjects and 24 healthy controls was analyzed. A disequilibrium measure, Jensen's divergence, was used to estimate the irregularity of neural dynamics. Results revealed...
We demonstrate the biopsy needle integrated with multi-pair electrode based impedance sensing device for biological tissue discrimination. The impedance sensing biopsy needle has several pairs of electrodes which enable the selective tissue analysis during biopsy process. In order to verify the usefulness of the device, we demonstrate the conductance measurement of various saline solutions and the...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.