The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
In recent years, there has been increasing interest in the use of automatic computer-based systems for the detection of eye diseases such as glaucoma, age-related macular degeneration and diabetic retinopathy. However, in practice, retinal image quality is a big concern as automatic systems without consideration of degraded image quality will likely generate unreliable results. In this paper, an automatic...
Structural changes in the choroid, a layer located between the retina and sclera, could indicate various vision impairments. Consequently, ophthalmologists inspect optical coherence tomography (OCT) scans of the posterior section of the eye towards making diagnosis. With a view to assist diagnosis, we propose an automated technique for segmentation of the choroid layer. Specifically, we detect the...
A conventional optical coherence tomography (OCT) system was set up in-house to image early dental caries, identify gap formation in the bonding interface for restoration and secondary caries. Two-dimensional images of tooth samples was obtained and dental defect were identified. A novel electro-optic tuning system is proposed in order to improve scanning speed and to perform noiseless imaging. Preliminary...
Intracoronary optical coherence tomography (OCT) is a new invasive imaging system which produces highresolution images of coronary arteries. Preliminary data suggests that the atherosclerotic disease can be detected from the intracoronary OCT images. However, manual assessment of the intracoronary OCT images is time-consuming and subjective. In this work, we present an automatic atherosclerotic disease...
This paper proposes an automatic method for the detection of lumen contours in intravascular OCT images with guide wire shadow artifacts. This algorithm is divided into five main procedures: pre-processing, an Otsu binarization approach, an intensity curve approach, a lumen contour position correction, and image reconstruction and contour extraction. The 30 IVOCT images from six anonymous patients...
An integrated instrument is being developed to study live cardiac trabeculae, which is capable of stimulating the muscle under controlled conditions while measuring the heat production, force, and sarcomere length distribution. To improve the accuracy of estimation of stress, strain, and volumetric heat production, the geometry of the muscle must be known. A spectral domain optical coherence tomography...
Speckle noise is problematic in optical coherence tomography (OCT) and often obscures the structure details. In this paper, we propose a new method to reduce speckle noise from multiply scanned OCT slices. The proposed method registers the OCT scans using a global alignment followed by a local alignment based on global and local motion estimation. Then low rank matrix completion using bilateral random...
The study of the mechanical and environmental factors that regulate a fundamental event such as fertilization have been subject of multiple studies. Nevertheless, the microscopical size of the spermatozoa and the high beating frequency of their flagella (up to 20 Hz) impose a series of technological challenges for the study of the mechanical factors implicated. Traditionally, due to the inherent characteristics...
Automated processing of digital histopathology slides has the potential to streamline patient care and provide new tools for cancer classification and grading. Before automatic analysis is possible, quality control procedures are applied to ensure that each image can be read consistently. One important quality control step is color normalization of the slide image, which adjusts for color variances...
Diffuse Optical Tomography (DOT) has become an emerging non-invasive technology, and has been widely used in clinical diagnosis. Functional near-infrared (FNIR) is one of the important applications of DOT. However, FNIR is used to reconstruct two-dimensional (2D) images for the sake of good spatial and temporal resolution. In this paper we propose a multiple-input and multiple-output (MIMO) based...
Smooth muscle cells (SMCs) play a pivotal role in regulating vascular tone in arteries, and are therefore an essential part of constitutive models of the artery wall. In the present study, we developed a method to quantify in 3D the orientation of SMCs in the intact artery wall. We stained cell nuclei in excised mouse carotid arteries mounted between micropipettes and imaged these in 3D using two-photon...
Optical projection tomography (OPT) is a very important imaging tool for a mesoscopic-scale. It can provide three dimensional (3D) transmission and emission imaging. However, high-resolution OPT is limited in depth of field (DOF) due to a high numerical aperture, which causes a poor performance of OPT in imaging large samples. Moreover, it is difficult to tune the focus plane (FP) to a fixed position...
Microdots are bright, 1–2um features of the cornea. It has not been proven what these dots represent, but they are thought to be remnants of apoptotic cell death, such as lipofuscin granules. Their presence has been shown to correlate with corneal aging and extended contact use, both of which are linked to oxygen deprivation in the cornea. Confocal images of the stroma show these microdots mixed with...
This paper presents a coarse-to-fine combined method for dealing with large displacement situations caused by low speed of frame rate in microscopic video sequences. Motion image estimation method utilizes the modified block matching method based on image warping to perform a wide range of changes in the amount of search comparison, and then using the optical flow method to fine adjustment pixel by...
Hyperspectral imaging system for diagnosing digestive diseases was newly developed in order to obtain information on pathology beyond morphology of lesions. In order to guide light reflected from a lesion, a baby fiber, which can be inserted in a forceps channel of the electronic endoscope, was also developed. The performance of the system was evaluated by animal experiment. Obtained hyperspectral...
This paper deals with the important issue of security and confidentiality of patient information when exchanging or storing medical images. Steganography has recently been viewed as an alternative or complement to cryptography, as existing cryptographic systems are not perfect due to their vulnerability to certain types of attack. We propose in this paper a new steganography algorithm for hiding patient...
Quantitatively assessing the tissue stiffness with acoustic radiation force impulse (ARFI) method has proved its worth in clinical trials. Much attention has been focused on the research of the displacement estimation algorithm in ARFI. However, the subsequent shear wave speed estimation part can also affect the accuracy and reliability of the results. In this study, several algorithms for shear wave...
Acoustic radiation force impulse (ARFI) technique is a quantitative method for tissue stiffness assessment. It has been proved to be less operator dependent than the quasi-static elastography, and has more simple hardware architecture than the supersonic shearwave imaging (SSI) technique, which make it easier to be miniaturized for some special clinical applications. However, unlike the SSI, ARFI...
One to five transvaginal ultrasound scans were taken of 63 women to estimate the microstructural changes in cervix using ultrasonic attenuation. Spectral log difference algorithm showed a clear decrease in attenuation as the time to delivery comes closer. The decrease in attenuation occurs earlier in preterm birth compared to full term birth which can be used as a predictor for preterm birth. Attenuation...
In this work an attempt has been made to enhance the edges and segment the boundary of intima-media layer of Common Carotid Artery (CCA) using anisotropic diffusion filter and level set method. Ultrasound B mode longitudinal images of normal and abnormal images of common carotid arteries are used in this study. The images are subjected to anisotropic diffusion filter to generate edge map. This edge...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.