The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The arc suppression coil determines whether it can effectively extinguish the arc when it is grounded in the neutral non-effective grounding system. An artificial grounding test is an importantway to verify its performance. In this study, 13 substations with the 10 kV system in the Ningxia areawere selected and considered. Based on the artificial single-phase grounding test, the residual current,...
A design gauge pressure of an eco-friendly gas insulated switchgear (GIS) with an application of vacuum interrupters (VIs) ranges from 0.1 to 0.3MPa. Therefore, a high differential pressure is imposed on bellows of the VIs, which increases the fatigue failure risk of the bellows after cycles of operations. Although, there are some empirical equations recommended by the Chinese National Standard GB/T...
The controlled switching technology of a short circuit current has been proposed for a long time. However, the opening time of the mechanism used in the high voltage circuit breaker is normally tens of milliseconds and has a variation of milliseconds. The electromagnetic repulsion mechanism has a very limited variation in the opening time. It provides a potential of achieving the controlled switching...
Predicting zeroes precisely and rapidly after a fault initiation is the basis of controlled fault interruption. However, none available algorithms could predict current zeroes within several milliseconds. The objective of this paper is to propose a fast estimation algorithm that can predict current zeros within 3ms after fault initiation. An algorithm is proposed based on an improved BP network. In...
With the expansion of the grid scale, short-circuit current is increasing, the safety of grid is seriously impacted by the short-circuit current. Therefore, a new technique of energy-saving transformer possessing variable impedance is proposed. This transformer combines the advantages of the high impedance transformer and fault current limiter, it can reduce the impact of short-circuit current and...
Fault current limiter (FCL) is one of the efficient technological measures to solve the increasingly serious problem of excessive short-circuit current in power grid. A fast breaker-type fault current limiter with modularized design is developed on the basis of 12kV fast-speed vacuum breakers and short-circuit current perfect forecast and zero-cross point precise phase controlled breaking technologies...