The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
The modeling, simulation and analysis of the energy conversion equations describing the behavior of a hybrid system PV and wind turbine, hybrid system for electrical power generation. A numerical model based on the aforementioned equations was developed, coded and results were compared to experimental data. The model is intended to be used as an optimization and design tool for such hybrid systems...
The output voltage range of renewable energy generations such as wind and photovoltaic can be influenced by the parameters of environment at a wide range, which can not satisfy the requirements of system for grid-connected operation. Therefore high-gain voltage inverter is important to integrate the renewable energy into the utility. For high-gain voltage and standard load voltage at low input DC...
An average power sharing control strategy for parallel operation of voltage source inverter (VSI) based modular Uninterruptible Power Systems (UPSs) is proposed in this paper. The presented method is based on a modified droop control. The proposed method conquers the drawback of conventional droop plus virtual impedance control, and at the same time some challenges in the real applications have been...
Permanent magnet synchronous motor (PMSM) drives include several design and control variables that affect power losses. The improvement in system efficiency through control techniques will reduce the size of inverter and motor cooling system as well as the operating costs of the system. This paper proposes a comprehensive analysis of loss controllability using various control parameters to reduce...
This paper presents a mixed three-level neutral point clamped (NPC) inverter with hybrid modulation method. It enables traditional Si devices and wide bandgap devices integration to reduce power loss and achieve high power density. Simulation results are firstly provided to verify the validity of the proposed approach.
This paper presents an ac ripple repression method for neutral-point voltage of three-level inverter system with electrolytic capacitor less. To reduce the volume of three-level inverter system, electrolytic capacitor with huge capacitance is must eliminated from dc-link. In the inverter system applying film capacitors, however, the ac ripple component in neutral-point voltage of dc-link is increased...
This paper presents a hybrid multilevel inverter with DC bypass. Mixed modulation method is proposed to balance dc voltage, and enables Si devices & wide bandgap devices integration to reduce power loss and achieve high power density. Simulation results are firstly provided to verify the validity of the proposed approach.
This paper proposes optimal switching period phase-shifted method for slave inverter to reduce grid current ripples in synchronized two parallel three-phase grid-connected voltage-source inverters (VSI). In parallel operation, a 180 degree phase shifted method generally takes of advantage of reducing grid current ripples in same DC-link voltage for each grid-connected VSI. However, in case of unequal...
This paper proposes an improved phase-shifted pulse-width modulation (PS-PWM) method for a three-phase cascaded H-bridge (CBH) multi-level inverter. In the proposed PS-PWM method, the switches at one leg of H-bridge cell (HBC) only operate and the switches at other leg are clamped. Therefore, the number of the multi-carrier signals depending on the voltage level can be reduced in half compared to...
In Digital Grid which has been proposed as a new electric power grid, multi-inverters are operated in parallel and it may cause the cross-current among those inverters, since inverters do not have synchronizing mechanism. In this study, the authors propose a method to control the cross-current caused by the difference in switching frequencies of multi-inverters in parallel operation. An indirect hysteresis...
In this paper, an improved grid voltage modulated control (GVM) with power compensation is proposed for grid-connected voltage inverters when the grid voltage is unbalanced. The objective of the proposed control is to remove the power ripple and to improve current quality. Three power compensation objectives are selected to eliminate the negative sequence components of currents. The modified GVM method...
In order to achieve the integration of ac/dc output in the aircraft power system, a novel single-input/dual-output indirect matrix converter (IMC) is proposed in this paper. Based on the fact that a real dc-link is formed in IMC, the proposed topology realizes dc output by inserting a simple two transistor forward converter (TTFC) into the dc-link. Its modulation strategy is composed of two parts,...
This paper presents an enumerated model predictive control (MPC) based method for the dynamic voltage restorer (DVR), which consists of a series-connected transformer and a voltage source inverter. The filter adopted in the DVR is a LC filter with a damping resistor. The design of the discrete model for the voltage source inverter and the corresponding controller are discussed in this paper. The proposed...
Traditional Z-source inverter can boost or buck voltage for its unique impedance network, but also has its own drawbacks, such as input current is not continuous, boost capacity is limited, the capacitor voltage stress is large and etc. In order to overcome the shortcomings of the traditional Z-source inverter, a series of Z-source inverters are proposed. In this paper, the topology of three kinds...
This paper proposes modeling and control system design for PV based Quasi-Z-Source Inverter (QZSI) for grid connected applications. The control system is designed based on the dynamical characteristics of the converter and introduces two cascaded controllers. Firstly, output current controller designed in the stationary frame. The second is DC-link voltage controller. Also, Modified Direct Incremental...
To study the impact on stability and security of the power grid that large-scale Photovoltaic (PV) generation systems integrated, the need for new models and simulation methods is increasing. Firstly, in this paper, a novel simplified phasor model is proposed based on the description of common detail model and averaged model for the PV generation system. The structure of the simplified phasor model...
Grid-connected inverter's output electric energy could trace the power flow, this is the prerequisite for the parallel operation of the photovoltaic power generation systems and the power grid systems operation. In order to achieve the parallel operation between the single phase photovoltaic system and The Grid, this paper presents a Grid-Connected control strategy of Grid connected inverter output...
This paper is concerned with the design of a fault estimation scheme with component fault and sensor noise for the three-phase inverter of high-speed trains. To design the component fault estimation observer, the three-phase inverter system states are augmented with the disturbance treated as new states, leading to an augmented and singular system. The observer is designed to generate the needed residual...
This paper presents the circuit model that is used for the cross-coupled charge pump design algorithm. Symbolic description of the pump stage model as an analog functional block for high-voltage application is firstly discussed. Design process has been done by using simplified BSIM model equations assuming the long channel MOSFET. Characteristics have been verified by ELDO Spice and compared with...
This paper analyzes the dynamic performance of FOC induction machines operating under current and voltage constraints. FOC rely on the proper performance of the inner current control loops. The capability of the machine to increase its torque can be seriously compromised due to the inverter voltage and current limits, which affect to the current regulator transient response. This can be especially...